Using an electronic lock
Use one of the methods below to
use the electronic lock.
Lock without adapter, power supplied via outdoor unit. When the
door is closed, the circuit voltage is 0 V. By unlocking the door the
circuit voltage is 12 V. Delay is 4~7 seconds.
Lock without adapter, power supplied via outdoor unit. When the
door is closed, the circuit voltage is 12 V. By unlocking the door the
circuit voltage is 0 V. Delay is 4 - 7 seconds.
Lock with adapter, power supplied by external adapter.
Answering unit
SEC-PH310